Detailed Release for the MT200A2W version 1.0.35A

This release details changes from version 1.0.35 to 1.0.35A

Checksum = 05200CDD

**BUG FIXES**
None

**ENHANCEMENTS**
1. Made a single line change in the SiLabs code to support the Si3217 with a new die from Vanguard.
SiLabs PCN note:
Impact on Form, Fit, Function, Quality, Reliability:
- There is no change to Fit, Quality, or Reliability of the Si3217x-B devices. All devices will comply fully with datasheet parameters and quality levels.
- The only change to form is that the new Si3217x-B product uses new high voltage die from Vanguard and a new version of the low voltage die from SMIC (Semiconductor Manufacturing International Corporation), modified for compatibility with the Vanguard HV die.
- To achieve functional compatibility, a minor software update is required for users of the Si3217x Revision B device. These software changes address minor differences between suppliers (Telefunken, Vanguard) of the high-voltage linefeed device (HVIC) that is part of the Si3217x. These changes will ensure correct operation of all supplier versions of Si3217x Revision B.